View Categories

85012M04 | HLG 100W 24V 4.2A Spec

Series: HLG
Version: V1.0
Manufacturer: TILLUME

1. HLG 24V 4.2A 100W Power Supply #

TILLUME HLG 24V LED Power Supply 100W

HLG-100-24V is a 100W LED AC to DC power supply with constant voltage output and active power factor correction design as its main features. This model can operate at an input voltage of 100~265VAC and provide an adjustable output voltage between 23V~27V. With a high protection level of up to 91%, IP65 and surface Passivation process design, the HLG-100H is suitable for both indoor and outdoor applications. With a lifespan of >62000 hours‧ a high conversion efficiency with a 7-year warranty, it adopts a fanless design and can operate in a case temperature range of -40°C~+80°C under natural air cooling.

2. Electrical Specifications #

Output #

MODELRated Value Note1
DC Voltage24V DC
Rated Current4.2A
Rated Power100W
Ripple & Noise (max) Note2100mVp-p/115Vac, 50mVp-p/230Vac
Voltage ADJ. Range23-27V
Voltage Tolerance±1.0%
Line Regulation±0.1%
Load Regulation±2.0%
Set Up, Hold up Time350ms, 60ms@230VAC 810ms, 15ms@115VAC at full load

Input #

MODELRated Value
Input Voltage Range100 ~ 265V AC
Frequency Range47 ~ 63 Hz
Efficiency (typ.)91%
Standby power70mW/115Vac, 100mW/230Vac
AC Current (typ.)0.99A/115Vac, 0.49A/230Vac
Inrush Current (typ.)Cold Start 35A/115Vac, 70A/230Vac
  • Note1: Unless otherwise specified, all specifications are measured at 230VAC input, rated load, and 25°C ambient temperature.
  • Note2: Ripple and noise measurement method: Use a 12″ twisted pair cable with 0.1 and 47 capacitors connected in parallel at the terminals and measure at 20MHz bandwidth

Protection #

Over Load #

Output VoltageData Note3
24V5.5A
25V5.4A
26V5.4A
27V5.3A
  • Note3 : Test conditions: Ambient temperature 25°C, test after 2 hours of full load operation.
  • Note4 : When Enter Over Load Protection, System entering hiccup mode, it can automatically recover after the abnormal load condition is removed
MODELData
Over Voltage Note528.4-29.5V
Short Current ProtectionYes
  • Note5 : System entering hiccup mode, it can automatically recover after the abnormal load condition is removed

3.Mechanical Structure #

Physical Parameters #

ParameterData
Housing Material6063 Aluminum / Passivation Note6
WiresH05RN-F 1.0mm2
IP GradeIP65
Dimension67*40*226mm(W*H*D)
Weight800g
  • Note 6: There may be slight scratches on the outer surface due to the Passivation process
TILLUME HLG100 24V Power Supply

4. Environmental Adaptability #

ParameterData
Work Temperature-25℃ ~ +70℃
Storage Temperature-25℃ ~ +80℃
Humidity45%-75% RH
Lifespan>62,000hrs @Ta=25℃

5. Conformity List #

EMC Directive Related Standards​Test Level
EN 55032 / ConductedClass B
EN 55032 / RadiatedClass B
​EN 61000-3-2 / Harmonic CurrentClass A.
​EN 61000-4-2 / ESDLevel 3
​EN 61000-4-3 / Radiated SusceptibilityLevel 3
EN 61000-4-4 / EFT. BurestLevel 3
EN 61000-4-5 / SurgeLevel 4
EN 61000-4-6 / ConductedLevel 3
EN 61000-4-8 / Magnetic FieldLevel 4
EN 61000-4-11 / Voltage Dips and interruptions>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods