Series: ExpertVersion: V1.0Manufacturer: TILLUME
1. 8W 24V Dimmable Spot #
Dimmbale 24V LED Spot
2. Core Parameters #
Optical Performance #
Remarks: The spot should work with constant voltage PWM dimmers operated by KNX, DALI, DMX, Loxone.
Note 1 : The Luminous Flux consistency deviation range is approximately ±10%.
Note 2 : CCT tolerance is ±50K.
Note 3 : The Vaule is General color rendering index (Ra)
Note 4 : All tests were conducted under controlled ambient temperature conditions (25°C)
Electrical Characteristics #
Parameter Rated Value Note.5 Power 6W Input Voltage 24V 1. Min. Input Voltage 22V 2. Max. Input Voltage 25V Current 0.35A
Note5 : the wattage consistency deviation range is approximately ±5%
Note6 : Test recorded after 1 hour of continuous operation.
Dimmable and Tunable White #
Parameter Data Dimming Methods 24V PWM Support PWM Frequency 100Hz to 20KHz Note7 Dimming Range 0.1%~100% Note8 Compatibility & Noise Matching the mainstream controller in the market Note9
Note7 : The Spot circuit response time is minimum 100nS, Considering that high-frequency PWM will cause EMC problems and require higher controller performance, we recommend a dimming frequency of no more than 8KHz.
Note8 : The dimming depth generally depends on the performance of the LED controller. As long as the time of one cycle is greater than 500nS, the spot will work normally.
Note9 : We know that customers use the with MDT, LUANTONE, LOXONE controllers and work well.
3.Mechanical Structure #
Physical Parameters #
Parameter Data Housing Material 6063 aluminium Heat Structure Fin design Chip Type COB IP Grade IP20 Dimension 49.5*50mm Cable Length 150mm Weight 50g
24V tunable white LED spot 8+8W dimension
4. Environmental Adaptability #
Parameter Data Work Temperature -25℃ ~ +60℃ Storage Temperature -25℃ ~ +80℃ Humidity 45%-75% RH Lifespan >50,000hrs @Ta=25℃
5. Wires Connection Identification #
Red Wire Connect power supply 24V positive Black Wire Connect power supply GND WW negative
6. Conformity List #
EMC Directive Related Standards Requirement EN 55015 Limitation of radiated and conducted emission for electrical lighting equipment. EN 61547 Immunity requirements of equipment for general lighting purposes. EN 61000-3-2Limitation of harmonic current emissions (equipment input current ≤ 16 A per phase). EN 61000-3-3Limitation of voltage changes, voltage fluctuations, and flicker in public low-voltage supply systems.
Safety Standards for Lighting Equipment Requirement EN 60598-1 Safety of luminaires – Part 1: General requirements and tests. EN 61347-1 Safety of lamps and lamp controlgear – Part 1: General requirements and tests. EN 61347-2-13 Particular requirements for electronic control gear for LED modules. EN 62031 Safety specifications for LED modules for general lighting.
Photobiological and Electromagnetic Safety Standards Requirement EN 62471 Photobiological safety of lamps and lamp systems. EN 62493 Assessment of human exposure to electromagnetic fields from information technology equipment.